ENG
PLN
You are here: Products Chimney systems Training chimney systems KD - a system of insulated chimney liners made of acid-resistant steel

System of insulated chimney cartridges made of acid-resistant steel

Diameter:
Sheet thickness [mm]:
Length [m]:
Sort:
Per page:
INSULATED PASSAGE KD 1 MM
INSULATED PASSAGE KD 1 MM
384.99PLN
RELIEF CONSOLE KD 1 MM
RELIEF CONSOLE KD 1 MM
384.99PLN
CONICAL REDUCTION KD 1 MM
CONICAL REDUCTION KD 1 MM
448.95PLN
INSULATED DAMPER KD 1 MM
INSULATED DAMPER KD 1 MM
512.91PLN
INSULATED 90 ° ELBOW WITH A CLEARANCE KD 1 MM
INSULATED 90 ° ELBOW WITH A CLEARANCE KD 1 MM
507.99PLN
INSULATED ELBOW 90 ° KD 1 MM
INSULATED ELBOW 90 ° KD 1 MM
389.91PLN
INSULATED ELBOW 60 ° KD 1 MM
INSULATED ELBOW 60 ° KD 1 MM
367.77PLN
INSULATED ELBOW 45 ° KD 1 MM
INSULATED ELBOW 45 ° KD 1 MM
293.97PLN
INSULATED ELBOW 30 ° KD 1 MM
INSULATED ELBOW 30 ° KD 1 MM
284.13PLN
CANOPY 3 KD 1 MM
CANOPY 3 KD 1 MM
111.93PLN
CANOPY 2 KD 1 MM
CANOPY 2 KD 1 MM
212.79PLN
CANOPY 1 KD 1 MM
CANOPY 1 KD 1 MM
104.55PLN
Next page

CHARACTERISTICS OF KD SYSTEM

KD Chimney system Insulated pipes and fittings exhaust system for open chamber heating appliances burning gas and oil. KD system is produced from stainless steel of proper chemical composition, that guarantees it's acid-resistance. During gas or fuel oil combustion acidic oxides are released. Acid produced during such a reaction is very dangerous for steel. That's why it is so important that steel should be resistant for the action of such chemicasl compositions. KD system produces liners of following thickness 0,5 mm, 0,8 mm, 1,0 mm

WHEN KD SYSTEM IS TO BE USED AND WHAT ARE IT'S ADVANTAGES

KD system is chimney liners system. Regular thickness, that can be found at price lists, averages 30 mm. Upon individual request we are able to manufacture product of 50 mm thickness. The very first argument, that suggest choice of KD system is open chamber heating appliance. Open heating chamber appliances are marked as appliances of class B according to the EKUG (European Classification of Heating Appliances). They are characterized by uptake of surrounding air which is necessary for combustion process. Exhaust gases are carried away by chimney duct. The necessity of chimney that is built outside the house constitutes another relevant apect. As we already know, chimneys that are built outside must have an insulation, which protects it's walls from over chilling.

External chimney is especially exposed to every temperature changes. As a result of chimney walls over chilling, it comes to fuel cooling and chimney draught disturbance. An insulation is to protect from such an effect.

The basic advantage for KD system users is safety, that is provided by tight pin-muff coupling. Currently it is considered as the most important argument among our customers. Possibility of chimney building without having a chimney shaft is another advantage.

Application of insulation (mineral wool) with appropriate technological parameters, U value: λ=0,040 W/m*K and temperature durability: 300º ensures appropriate thermal insulation. Construction of chimney shaft generates additional costs and very often unnecessary modifications in building structure. KD system allows to avoid all unnecessary work as it does not requre chimney shaft. It is az independent construction, properly supported and fixed to building's wall with a clamp. Attractive design is relevant according to it's external location. Shining steel is a perfect material that is aesthetic as well as it perfectly reflects the light giving additional visual effect.

WHAT SHOULD BE REMEMBERED BEFORE PURCHASE OF KD SYSTEM

When we are sure that in our building there is no chimney shaft, where the stack system can be placed as well as we realize that the only one way is to build chimney outside the building and we dispose of open heating chamber burning gas or fuel oil, then KD system is an ideal solution. When we are decided for purchase, it is to remember that all basic information should be collected to allow selection of appropriate system parameters. The most relevant information concerns the diameter of chimney liner. Insulated chimneys consistes of liner, insulation and external jacket. The diameter of a liner should be matched so, that it will provide right chimney draught. It should be adjusted to the parameters of heating appliance as well as to a stack high. The liner's diameter is already known. The next information we need is insulation thickness. There are two solutions traditional insulation of 30 mm thickness or insulation manufactured upon customer's individual request (thickness: 50 mm). Usually in case of that system, the insulation of 30 mm thickness is sufficient. We know already the diameter and insulation thickness. Still we have to know the high of our chimney. The high of a chimney determines the amount of necessary elements i.e. pipes, fixing clamps or installation grips.

Moreover we have to know the diameter of boiler outlet pipe and the distance between heating appliance and installed chimney. That information is required for selection of proper connection parts. If the diameter of a boiler outlet pipe differs from the diameter of chimney duct it is to remember that the reduction is necessary needed for proper diameter fitting. Collected data ensure us the peace of mind and we can be pretty sure that the chimney system we buy is completed and there will be nounpleasant surprises according to shortage of particular parts or their unsuitable dimensions.

CORRECT INSTALLATION GUARANTEES NON-FAILURE OPERATION OF STACK SYSTEM. PRACTCAL INSTRUCTIONS FOR LONG-LASTING CHIMNEY OPERATION

Installation of chimney system constitutes one of the main factor that influences on proper functioning. According to that it should be carried out by specialized team. First of all you should prepare the place for installation works. You should prepare also all openings in wall that are necessary for installing of heating appliance connectors to the chimney duct. After conducting above mentioned activities you can start working with the right installation of chimney duct. It is relevant to connect each element properly as any negligences are unacceptable in order to user's safety, that is provided by tightness of installation. Chimney duct should be installed vertically. For this purpose fixing clamps every 2 rm are recommended to be used. In case of insulated chimneys you should focus your attention on proper fasting of stack to the building walls. External chimney are especially exposed to the external corrosion factors like wind or snow that interact with its structure. Owing to that fact fixing of the chimney should be resistant to that factors and protect it from falling down. In this case we have to know wall layers where the chimney will be fixed. It will protect us from such mistakes like fixing the stack to the non-supporting wall layer (e.g. insulation layer) that can contribute to collapsing of whole chimney construction. After installation, the last thing to do is to check the functionality of chimney system and to enjoy its proper and long-lasting work.

KD SYSTEM ENSURES:

- high quality

- possibility of selection of proper liner's diameter.

- possibility of chimney installation outside the building.

- safety and usage comfort

- easy installation

- users satisfaction

- attractive design

DESTINATION Open chamber heating appliances
Fuel type Gas/ fuel oil
Available diameters Dn 60-Dn 500, larger diameters upon individual request
Core steel thickness 0,5-1,0 mm
Thickness of jacket steel 0.5 mm
Type of jacket steel 1.4301, 1.4404, 1.4571 or other according to PN-EN 1856-1
Type of jacket steel 1.4301, 1.4404, 1.4571 or other according to PN-EN 1856-1
Type of connection Socket
Temperature class T 450
Pressure class N1 (pressure of 40Pa)
Operation mode Negative pressure
Condensate resistance W
Soot fire resistant G 1000
Corrosion resistance Vm
Insulation Mineral wool, thickness 30mm, density 80 kg/m3, other upon
individual request.

Typical chimney construction consists of following
elements:
or another elements according to the customer's need:
  • pipes: KD-R10, KD-R05, KD-R02, KD-RT,
  • tee-pipe- element connecting flue with chimney: KD-TR90, KD-TR45,
  • cleanout: KD-WTD, KD-W-DWL, KD-WOP-DWL, KD-WO-DWL,
  • Condensate collector with plate KD-O,
  • mouth-end or awning covering KD-U, KD-D(W1), KD-D(W2), KD-D(W3) liner,
  • KD-ZID, KD-ZI top or bottom insulation end,
  • pipe with connections: KD-RKC05, KD-RKM05,
  • elbows: D-K30, KD-K45, KD-K60, KD-K90, KDKW90,
  • fixing clamps KA-OM,
  • clamps KA-ZM,
  • reductions KD-RS,
  • draught controllers,
  • chimney pots- granting chimney drought independence of the wind
  • condensate eliminator,
  • supporting structure
  • dampers KD-S.

All chimney systems we manufacture meet high quality requirements, which are confirmed by the obtained certificates. The issuer of the certificates is MPA NRW - MATERIALPRÜFUNGSAMT NORDHEIN-WESTFALEN, a recognized independent institute for testing product compliance with standards. Due to the laboratory capabilities, experience and staff of specialists, it is the most recognized institution controlling compliance with standards.

Our address
Our address

Łężkowice 112 32-015 Kłaj

Write to us
Write to us

sklep@kominus.com.pl